    Fuse & Breaker Sizing

    Watts don't pick fuses — amps do. Choose your system voltage:

    PLEASE NOTE: these amps are grid-based — please change to match your system voltage below. A 12V setup draws roughly 20× the amps for the same watts.

    Peak load (simultaneous)
    0.0A
    Main fuse / breaker
    5A

    Main fuse = peak amps × 1.25 safety margin, rounded up to a standard size. It protects the cable — size the cable for the fuse, never the other way round.

    What does my fuse allow?
    My fuse isA= 3,450W max

    at 230V. Any single load above that blows it — and keep continuous loads under 80% (2,760W) for fuse longevity.